Version: 1.0.6
Date: 2024-03-21
1. The SetGroup:Reset command now supports resetting all RTP-MIDI sessions. Resetting sets all session parameters and names to default values (all sessions are responder, are enabled, and have default names). Resetting will cause all sessions to be shut down and restarted so best not to do so when you have active MIDI data flowing in/out.
2. The internal automation control port now returns 0x02 (MIDI out only) for the MIDIPortInfo:PortSupportFlags parameter. Previous firmware returned 0x03 (MIDI in and out).
3. Fix problems with the SetGroup:Reset commands not working properly with MIDI global parameters.